Vme64x backplane. High Quality Chassis and Enclosures for VME and VME64x Applications. Vme64x backplane

 
High Quality Chassis and Enclosures for VME and VME64x ApplicationsVme64x backplane Backplanes compactPCI 3U, VME J1 or J2 STD Bus Vector designs and manufactures standard and custom VME, VME64x, CompactPCI backplanes

Gefährliche Spannung! Dieses Warnsymbol warnt vor gefährlicher Spannung. 002 VME / VME64x Manual Overview What is VMEbus The VMEbus started with the ANSI/VITA 1 specification in 1982. 8” pitch versus a typical 1. 1-1997 VME64 Extension Standard, ANSI/VITA 1. This configuration is based on a 16-slot VME64X backplane. 7 Increased Current. The VME64x system is backward compatible with the VME64 system. Where these charges should be7U VME64x Backplane 2-slot w/o P0, compliant with ANSI/VITA 1. Our serial backplane technology comes equipped with either single star or serial full mesh topology for the highest quality backplane on the market. Includes termination passive inboard, daisy chain automatic active, and power bugs on top and bottom of slots. 1-1997). - Contacts meet all requirements. The P1 connector carries most of the VME bus signals, between the board and backplane. 11 Single Slot Backplane. The various headers are basically the same, except the 12-pin friction lock for +/- V1 and V2 has only 8 pins (one less pin per type). The two ARINC drawings SK-141-10 and the SK-141-17 with detailed critical dimensions and tolerances for the initial 3 basic form factors, via the ½, 1 and 1 ½ ATR. VME64x Backplanes. IP 54/55 dürfen die Systeme nur in geeigneten Schrank- oder. It was added to the 160 pin P1/J1 connector in the VME64x specification. 62" h x 19. 0, November 19, 2007 1. +V1, -V1, +V2, -V2. : 73972-083 • Benutzeranleitung Netzteil Bestellnr. 5-2003 VME2eSST Specification, ANSI/VITA 1. The cPCI series are highly reliable, plug-in power supplies for CompactPCI and VME/VME64x systems, which are increasingly used in industrial, mil/aero, communications and other applications. 7 Increased Current. VPX-0557 25Gbps SOSA 14. VME64x versions in 12- and 16-slots; 21 slots for -HP version. VME64x Backplane, 6 U, 8 Slot Without P0 In accordance with ANSI/VITA 1-1994 VME64 Standard, ANSI/VITA 1. Open VPX is the architecture framework that defines system level VPX interoperability for multi-vendor, multi-module, integrated system environments. Includes termination passive inboard and daisy chain automatic active. Test adapter is held firmly in place by the front and lateral guides. 7-2003 (R2009) increased current level for VME (96 pin) and VME64x (160 pin) DIN/IEC connectors. 2. 3-997. VME / VME64x Backplanes. Hartmann Electronic’s slimmest 19” rack mountable VME solution – The VME64x 1U system. 1-5 slots. Part Number: 11-1011777-2119. VME64x extractor handles (on request) Standard VME supply voltages (+5 V, -12V) Possible future firmware extensions comprise. This platform conforms to VITA 1. 1-1997 while providing a low profile, practical packaging solution for high-performance. 1 and 1101. 2mm. It defines a set of features that can be added to the VME and the VME64 boards, backpanes and sub-racks. The VME backplanes ( VME, VME64, VME64X ) are specially designed to maximize performance, achieve excellent power distribution & best signal integrity. 20-Slot 6U Backplane. S33-1U CPCI. J2 Monolithic) conforms to: VITA 1. Item/Part Number. This line covers standard bus systems as CAMAC, VME, CERN VME 430, VME64x, VME64xP (VIPA)VXI and VXS but also custom spec. 002 VME / VME64x Manual Overview. 7-2003 (R2009) increased current level for VME (96 pin) and VME64x (160 pin) DIN/IEC connectors. • User Manual VME64x Backplanes Order no. 7 Increased Current. 1-1997, VME extension standard. Designed with the engineering developer in mind, the 524 Series development system incorporates a 9-slot OpenVPX backplane (9 payloads + 2 power slots) with profiles aligned to Sensor Open Systems Architecture (SOSA™) and C4ISR/EW Modular Open Suite of Standards (CMOSS) initiatives. VME64x System Subrack 4 U Safety 20836-416 1 R1. 5 A) • Mounting holes for optional connection to. DESCRIPTION VME64E02P01 2-SLOT VME64x J1/J2/P0 VME64E03P01 3-SLOT VME64x J1/J2/P0 VME64E04P01 4-SLOT VME64x J1/J2/P0 VME64E05P01 5-SLOT VME64x J1/J2/P0 VME64E07P01 7-SLOT VME64x J1/J2/P0 The 6U VME64x backplane has the same routing and basic design as the 7U line with a couple of exceptions. 101V64XC08-0621R. Steckkarten nach dem VME64x Standard (VITA 1. : 73972-103 • Short Form User Manual VME64x Backplanes Order no. 1, include a 12-layer low noise stripline design with outside layers, which incorporates a chassis ground EMI shield and are available in customer configurations. Our VME Backplanes are made for industrial applications in different form factors, including vertical and horizontal orientation of the backplane and cards. 01 Mar 1998. 1-1997 VME64x; ANSI / VITA 1. Backplane Height: Amphenol ABSI VME64x backplane offer 4 different height options covering 3U, 6U,7U and 9U. VME64xK - Military VME64xK backplane fitted with 5 row 160 pin J1/J2 & 75 pin key-slot J0 connectors have polarizing keys so that any given board fits only in its connector-coded slot, protecting against card insertion errors (ref: VME64xK). 3U backplane VME64x 1U/84HP 2 Slots. Highly competitive customization available. 7 Increased Current. VME64x backplanes must not bus or terminate this signal. 4. (V021) = VME 21-slot backplane (VX21) = VME64x 21-slot backplane with J0 connectors 9 5$&(ZDFHUWL¿HGKLJKSRZHU9,7$ FRPSOLDQW90( [ VORWEDFNSODQHZLWK- FRQQHFWRUV (VP21) = VITA 31. 5 inches preferred)VME64x System Subrack 4 U Safety 20836-416 1 R1. HARTMANN Electronic. : 73972-103 • Short Form Manual VME64x 6U Backplanes Bestellnr. German Headquarters Motorstr. Further information can be found in the user manual of the backplane: Order-Vector Electronics and Technology VME, VME64x, cPCI Chassis, System Enclosures, Backplanes, Subracks, Test ExtendersVME64x 6U 12-slot ackplane Enabling the Evolution of Technology Amphenol ackplane Assembly & System Integration Amphenol- SI have been designing, assembling and testing backplanes for more than 30 years. 1-1997) • Einer VME64x (VITA 1. Connector Type: DIN 41612, VME64x. All WIENER VME 64x multi-layer backplanes are outfitted with 5-row 160 pin connectors for J1 and J2 as well as optionally with 133 pin hard metric connector for J0. VITA 38-2003 (S2022), System Management on VME. 7 Increased Current. VME slave memory access. VME64X 6U 5 Slot with P0. 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VMEAdditional Information. Item Description. There are three general types of backplanes available: Standard, 3-row connector backplanes. The maximum form factor expands to a 21 slot backplane. Power Connector. : 73972-128 Die Benutzeranleitungen können im Internet bei heruntergeladen werden. 7-2003 (R2009) increased current level for VME (96 pin) and VME64x (160 pin) DIN/IEC connectors. High-speed backplane operation is a direct result of the improved OEC circuitry and high drive that has been designed and tested into the VME64x backplane model. VME64xK - Military VME64xK backplane fitted with 5 row 160 pin J1/J2 & 75 pin key-slot J0 connectors have polarizing keys so that any given board fits only in its connector-coded slot, protecting against card insertion errors (ref: VME64xK). Joos – Introduction to VMEbus 10 VMEbus basics • Classes of modules (logical) – Master • A module that can initiate data transfersThis backplane allows for plug-in of both Legacy or VME64x boards and VPX boards into the same backplane. VME64X 6U 5 Slot with P0. Elma / TreNew VME64x 9-Slot Backplane. VXS (VITA 41. 2. The 6U monolithic WIENER J1/J2 backplane fully complies with the VME64 Extensions specification according to ANSI/VITA 1. : 73972-103 • Short Form Manual VME64x 6U Backplanes Bestellnr. Our VME Backplanes are made for industrial applications in different form factors, including vertical and horizontal orientation of the backplane and cards. VPX, cPCI, VME64x, VXS, VXI, PXI, PXIe, ATCA, cPCIe, 2. See the other products Elma Electronic. Exhibit with us. An optional advanced system monitor provides status of all power supply outputs, fan speeds, and VME64x Backplane, 6 U, 11 Slot Without P0 In accordance with ANSI/VITA 1-1994 VME64 Standard, ANSI/VITA 1. S34-HP VME64X. Description. Hartmann Electronic’s 4 slot 19” rack mountable VME solution – The VME64x 2U system. This platform conforms to VITA 1. Includes termination passive inboard, daisy chain automatic active, and power bugs on top and bottom of slots. The backplane trace impedance can vary between 45 Ω and 60 Ω, the stub impedance is about 60 Ω, and the connector impedance is about 67 Ω. Backplane VME64x J1/J0/J2. VME / VME64x Backplanes. The Elma Electronic VME64x backplane series is designed to fully comply with the ANSI/VITA VME extension standard. 101V64XM18-0620R. 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VME Table of Contents, Abstract and Foreword Do not specify or claim conformance to this draft standard VME64x, VITA 1. Over the evolution of its near 40 years of existence, VME-bus has become a worldwide standard and is still used in a wide variety of. Elma also offers carrier card design. 23001-065) 4 1 Power supply unit, open frame; 250 : W (part no. These specifications support. VME BACKPLANES VME64X, VME320 BACKPLANES VXI BACKPLANES COMPACTPCI BACKPLANES SWITCHED FABRIC BACKPLANES CUSTOM BACKPLANES ACCESSORIES Index 1. 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VMEBackplane VME-J1. 1-1997 VME64 Extension Standard, ANSI/VITA 1. VPX-0433 3U 25Gbps VITA 67. 5-2003 VME2eSST Specification, ANSI/VITA 1. VPX, based on switched fabrics, essentially evolved from the VMEbus backplane architecture, which is bus-based. This thin VME chassis comes with a 250W cPCI hot-swap power supply and horizontally oriented card slots. • User Manual VME64x Backplanes Bestellnr. Extended Description. VME64x 2U/84HP 4 Slots. 5 References and Architecture Specifications • User Manual VME64x Backplanes Order no. 1-1997, VME extension, and VITA 1. 7 Increased Current. Backplane Part Number: 32VS-0416-TV07645X-P250. IP 54/55 dürfen die. Vector uses ERNI P0 connectors. The extra 1U provides room for extra power bugs or busbars. Seventeen models are available offering from five to 21 slots. Extended Description. Bei höheren Anforderungen an die Schutzklasse, z. As VXS is based on a 0. Technical Specifications Backplane Compatibility: ANSI/VITA 1-1997 VME Extensions standards; PICMG 2. Includes termination passive inboard, daisy chain automatic active, and power bugs on top and bottom of slots. The OpenVPX framework defines clear. VME64x Backplane, 6 U, 10 Slot Without P0. The SN74VMEH22501A is pin-for-pincapatible to the SN74VMEH22501 (TI literature number SCES357), but operates at a wider operating temperature (−40°C to 85°C) range. The backplane is actively terminated and provides automatic. 7 compliant VME64x 21-slot backplane with J0 connectors (VX21) = RACEway certified VME64x 21-slot backplane with J0 connectors (V021) = VME 21-slot backplane (VP21) = VITA 31. Vector offers a VMEbus and VME64x J1 only backplanes currently in 21, 16, 15, 10 and 9 slots per ANSI/VITA 1. cPCI Serial Backplanes. The product, VME64x bus specification or ANSI/VITA 1. 1, November 14, 2008 1 Safety 1. VPX is a broadly defined technology utilizing the latest in a variety of switch fabric technologies in 3U and 6U format blades. Includes termination passive inboard, daisy chain automatic active, and power bugs on top and bottom of slots. 101V64XC05-0621R. VME64 and VME64x (optional) comes with an enhanced connector. System Slot: Slot 1 Left. While different from the traditional VME64 P0/P1/P2 backplane architecture, VPX can be compatible with legacy systems in "hybrid" backplanes. • User Manual. High-speed backplane operation is a direct result of the improved OEC™ circuitry and high drive that has been designed and tested into the VME64x backplane model. 3 19" Industrial Chassis Environmental Specifications Temperature D0-160E §4 Operating: -20° to 65° C / Non Operating: -40° to 85° C2. 1 test vectors to a system composed of nineteen boards, called here units under test (UUTs). 7 Increased Current. 1, and V67. 5 Gbps Pci-Express and RapidIO are vehicled on the classical VME64x backplane 3M column-based differential pair B19 HSHM model as P0 SBC connector Customer investments preserved: VME64x, VITA31,. 8" pitch). Subrack based, sheet metal, desktop or tower configurations. For +12 V and -12. SMT Line The Elma Bustronic SMT line is over 40’ long and includes an in-line printer, a pick-and-place SMT assembly machine, re-flow. VME64x Backplane Card Card Card Card RT2211 3. VME64x Backplane, 6 U, 3 Slot With P0 In accordance with ANSI/VITA 1-1994 VME64 Standard, ANSI/VITA 1. There are major new features on this product for a more faster output which. VME64x System Subrack 8 U Product Definition 20836-820 2. 6U VME64x Backplane 8-slot with P0, compliant with ANSI/VITA 1. 056-301 6U/149 W air cooled load board for VME64x backplaneVME64x backplane. VME / VME64x Backplanes. 3 VME64x Backplane The horizontally assembled 6 U backplane (J1. Five rows instead of the 3 rows used in the original VME specification. 73972-103 Rev. 1-1997 VME64x; ANSI / VITA 1. High-Quality Backplane Solutions for VME and VME64x Applications. 3c, V67. These pins may also be used as additional +5 VDC power pins in boards that do not support live insertion. The backplane is actively terminated and provides automatic daisy chain either. Some systems have obstructions such as power supplies behind J1 which prevents direct insertion of RTM’s. 3 VME64x Backplane The horizontally assembled 6 U backplane (J1. 1-1997 VME64 Extension Standard, ANSI/VITA 1. PICMG ATX 1-5 slots. The new 160 pin DIN (5 row x 32 pin) adds rows "z" and "d". Backplanes. 1-1997)). 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VMEStock # 76283-1. 7 Increased Current. Further information can be found in the user manual of the backplane: Order-VME64x Backplane, 6 U, 5 Slot With P0 In accordance with ANSI/VITA 1-1994 VME64 Standard, ANSI/VITA 1. 1 Intended Application The VME64x system subrack, described in this manual, is intended as a platform for a microcomputer system based on the VME64x bus system (VITA 1. CompactPCI backplane 102CPCI306-20X0. Height: 6U :VME64x Backplane, 6 U, 3 Slot With P0 In accordance with ANSI/VITA 1-1994 VME64 Standard, ANSI/VITA 1. 12" w x 10. backplane VME64x. The extra 1U provides room for extra power bugs or busbars. Slot ID (set by VME64x backplane) Data Type: Event Header Type: 0x2 Size: 1 word Description: Indicates the start of an event. 16-Slot 6U OpenVPX Gen3 Backplane. 1 Intended Application The VME64x system subrack, described in this manual, is intended as a platform for a microcomputer system based on the VME64x bus system (VITA 1. VME64x BACKPLANES // Product Information Dimension diagrams J1/J2 VME64x Front view W1 = total width n = number of slots PCB thickness = 3. 1-1997, VME extension, and VITA 1. The B-port I/Os are optimized for driving large capacitive loads and include pseudo-ETL input thresholds (½ V CC ± 50 mV) for increased noise immunity. All WIENER VME 64x multi-layer backplanes are outfitted with 5-row 160 pin connectors for J1 and J2 as well as optionally with 133 pin hard metric connector for J0. Wide range of VPX backplanes designed for your ruggedized applications: compliant to VITA specifications, with or without RTM, 3 U and 6 U available. Typical plug-in modules are 3U or 6U with a 160mm depth. : 73972-077 • Benutzeranleitung Power-BusplatineVME64x Backplanes Fremont, Calif. Elma Electronic's 32190-0000 is a vme64x backplanes. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. Monolithic 6U high VME64 and VME64x backplanes are fully RoHS compliant and perform to ANSI/VITA 1. 1-1997, VME extension, and VITA 1. 0. Add to Cart. The VME backplane is a double-terminated backplane. Item Description. OpenVPX, CompactPCI, VME, and VME64x are open standard backplane architectures commonly used in Eurocard systems. Test adapter allows measurement and testing of both 3 and 6U assemblies (CompactPCI, VME64x) Test adapter can be mounted in chassis with an overall depth of up to 220 mm. With voltage tolerances, the 60 volt maximum is exceeded. Includes termination passive inboard and daisy chain automatic active. 6U VME64x Backplane 5-slot without P0, compliant with ANSI/VITA 1. In accordance with ANSI/VITA 1-1994 VME64 Standard, ANSI/VITA 1. 1-1997 VME64x; ANSI / VITA 1. The VME64x system subracks are designed for protection class IP 20 and canBACKPLANE (V721) = RACEway certified high power VITA 1. operating at LVTTL logic levels and VME64, VME64x, or VME320(1) backplane topologies. Primary. Elma is a leading contributor to the DoD hardware convergence and tri-service commonality initiatives, providing CMOSS / SOSA-aligned technology, backplanes and modules pursuant to the stated goals of those initiatives. Backplane Type: VME64x with EDC. 2mm. Includes V67. Transition modules do not connect to VMEbus but just to the VMEbus module on the opposite side of the backplane via the user defined pins of the J0, J2 and. VME64x Backplane, 6 U, 5 Slot Without P0 In accordance with ANSI/VITA 1-1994 VME64 Standard, ANSI/VITA 1. In accordance with ANSI/VITA 1-1994 VME64 standard 3 U with J2 plane Connection or isolation between the digital GND and chassis GND can be changed via screw Termination passive Supply voltages can be provided via powerbugs (ring tag M4) or FASTONs Multiple backplanes can be placed. High-Speed Backplanes. We offer all standard features required for VME64x compatibility, including 160-pin VME extension connectors in J1 and. 25” de-vices. 8 VMEbus basics • Electrical properties – All lines use TTL levels – Low = 0. Die VME64x Einschubsysteme erfüllen die Schutzklasse IP 20 und dürfen deshalb nur in den entsprechenden Umgebungen eingesetzt werden. The new 160 pin DIN (5 row x 32 pin) adds rows "z" and "d". 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VMEStock # 76283-1. With voltage tolerances, the 60 volt maximum is exceeded. 1 May 04, 2009 Technical data fans updated Impressum: Schroff GmbH D-75334 Straubenhardt, Germany The details in this manual have been carefully compiled and checked - supported by. VME J1/J2 & VME64x J1/J2/P0, Monolithic 6U Backplanes, 2 to 21-Slot VME64x 160-pin Vectorbord® Backplanes VME & VME64x Backplanes VMEBP07P00 Rear View VME64E21P01 Front View Ohm Resistance of signal lines. High Quality Chassis and Enclosures for VME and VME64x Applications. Extension of VME64x RTM boards from rear of backplane. Product Information. SIS Documentation SIS3820 VME Scaler Page 9 of 83 4 Functionality VME. 1-1997, VME extension standard Exceeds ANSI/VITA 1-1994 and IEEE P1014 specifications 10-layer. 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VMEThe Bustronic VME64x backplanes come with power bugs for +5V, +3. It defines: VME and VME64x Systems. 1 s lot 6U VPX, 2 slots 6U VXS, 3 slots 6U VME64x no/P0 VISIT US 8221 East Evans Road Scottsdale, AZ 85260 • Mapare “C” (6U x 340mm) and “D” (9U x 340mm) and the backplane pitch is 1. Hartmann Electronic is an industry leader in the designing, manufacturing and production of. High-speed backplane operation is a direct result of the improved OEC circuitry and high drive that has been designed and tested into the VME64x backplane model. 1, and V67. connector. VME / VME64x Backplanes J1 Backplane: The basic configuration is the 3U high (Single Eurocard) J1 plane. The Elma Bustronic VME64x backplane series is designed to fully comply with the ANSI/VITA VME extension standard. Includes termination passive inboard and daisy chain automatic active. Hartmann Electronic is an industry leader in the designing, manufacturing and production of backplane technology, including VME and VME64x. By utilizing a rugged contact system, our VME64x connectors can withstand the shock and vibration environments that other. Chassis – Turnkey, Fully Assembled and Tested, Convection, Conduction and Liquid Cooling. This Dawn VME DEV-7713 VME64x Tabletop Development Chassis is used and in excellent condition. x) adds a high-speed MultiGig connector over P0 of a VME64x backplane for serial data traffic. 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VMEVME64x. The VITA31. Hartmann VXI Backplanes are at the forefront of the standard, representing the highest quality and system performance. 7 Increased Current. This platform conforms to VITA 1. VME64x backplane. Backplane Height: Amphenol ABSI VME64x backplane offer 4 different height options covering 3U, 6U,7U. Serving physics research and other demanding high-performance test and instrumentation applications W-IE-NE-R has developed a line of backplanes and accessories in various bus architectures. Includes termination passive inboard, daisy chain automatic active, and power bugs on top and bottom of slots. Part Number: 11-1011777-2119. Five rows instead of the old 3 rows used in the original VME specification. Subrack based, sheet metal, desktop or tower configurations. The extra 1U provides room for extra power bugs or busbars. The maximum form factor expands to a 21 slot backplane. 5-2003 VME2eSST Specification, ANSI/VITA 1. The VME64, VME64x represents an extension of the VME family. Gefährliche Spannung! Dieses Warnsymbol warnt vor gefährlicher Spannung. • User Manual VME64x Backplanes Bestellnr. 6U OpenVPX Backplanes. The VME64x backplane supports 19” rack applications. Architecture: VME, VME64x : Product Type: VME64x : Slots: 15 : Technical Information. Extended Description. It was added to the 160 pin P1/J1 connector in the VME64x specification. We are a key VITA Technologies contributor member for the definition and development of OpenVPX™ and SOSA™ standards. 3c, V67. The extra 1U provides room for extra power bugs or busbars. The same style of connector is also used for switch slots, driving the centralized fabric signals. 1-1997, VME extension, and VITA 1. 1-1997 VITA 38 systems management for VME At the right side is a connector for the power supply, at the left side a connector for the Fan Tray. Item/Part Number. Available in 3, 9, 10 and 21 slot configurations, there is an. The extra 1U provides room for extra power bugs or busbars. TRANS-GP7U VME64x Backplane 5-slot with P0, compliant with ANSI/VITA 1. 2. com, a global distributor of electronics components. 1 Gigabit Ethernet VME64x backplane, VITA 38 IPMB to all slots, 2 fabric slots, 19 node slots XXXX Notes: 1. System Slot: Slot 1 Left. Die VME64x Einschubsysteme erfüllen die Schutzklasse IP 20 und dürfen deshalb nur in den entsprechenden Umgebungen eingesetzt werden. Features and benefits include: • Metal shells - mount directly to the standard VME card mounting holes, providing support and protection to the inserts in the module and additional stiffness to the backplaneDawn provides extensive backplane customization tools with full prototype to production capability. Hot swap (in conjunction with VME64x backplane) VME64x Connectors VME64x Side Shielding VME64x Front panel VME64x extractor handles (on request) single supply (+5 V) in field firmware upgrade capability. Hybrid VXS + VME64x Backplane; Conforms to ANSI/VITA41. Gigabit Ethernet on VME64x Backplanes: This standard defines a pinout and interconnection methodology for implementing a 10/100/1000BASE-T Ethernet switched network on a VME64x backplane. The retry cycle prevents deadlock (deadly. VME / VME64x Backplanes. ANSI/VITA Stabilized Maintenance: $25: Free: ANSI/VITA. ELMA Electronic, Inc. The design of VME64x backplanes is also typically much simpler. J2 Monolithic) conforms to: VITA 1. 1-1997 VME64 Extension Standard, ANSI/VITA 1. 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VMEare “C” (6U x 340mm) and “D” (9U x 340mm) and the backplane pitch is 1. 3 volts) and ground (GND) on P1 and 'User Defined' on P2 (next page). The VPC pins are connected to the +5 VDC power supply on VME64x backplanes. (For OpenVPX products, see the Pixus OpenVPX section. 1-1997 VME64 Extension Standard, ANSI/VITA 1. VME64x backplanes must not bus or terminate this signal. 3 + 5 V + 1 2 -1 2 F A N T E M 10006841 VME64x Backplane Fan Tray Front card cage Rear card cage Air filter Power Supply Fan Control Module (FCM) Page 10: SubrackHot swap (in conjunction with VME64x backplane) VME64x Connectors. VME64 and VME64x (optional) comes with an enhanced connector. 0, July 14, 2009 1 Safety 1. Speeds up to 100GbE. Includes termination passive inboard and daisy chain automatic active. Bare Board: VME64x. This platform conforms to VITA 1. Fits any Eurocard packaging standard based card cage as it meets the form factor and mounting provisions called out in the VITA Specification. Subrack based, sheet metal, desktop or tower configurations. Hartmann VXI Backplanes are at the forefront of the standard, representing the highest quality and system performance. VME64 and VME64x (optional) comes with an enhanced connector. 20-Slot 6U Backplane. All VME64x systems require a minimum of level 2 performance. A31 • There is no A00 address line on the backplane. Includes termination passive inboard and daisy chain automatic active. 5-2003 VME2eSST Specification, ANSI/VITA 1. 6 mm. Product Overview. 3 VME64x Backplane The horizontally assembled 6 U backplane (J1. 7 Increased Current. Show per page. The 3U WIENER VME-J1 backplane fully complies with ANSI/VITA 1-1994 and IEEE-1014-1987 specifications. Five rows instead of the old 3 rows used in the original VME specification. Hartmann Electronic is an industry leader in the designing, manufacturing and production of backplane technology, including VME and VME64x. 7 Increased Current. Home » Backplanes » VME / VME64x Backplanes. A DIN41612 connector can be used in VME64x system. 1-1997, VME extension standard. 1-1997, VME extension standard. 110, PXI and CompactPCI along with switched fabric configurations. 1-1997 VME64 Extension Standard, ANSI/VITA 1. VME Backplanes VME64x Backplanes Operating Temperature -25°C - +85°C (active termination) -40°C - +85°C (passive termination) -40°C - +105°C (on request) Storage. VME64x versions in 12- and 16-slots; 21 slots for -HP version. The B-port I/Os are optimized for driving large capacitive loads and include pseudo-ETL input thresholds (½ V CC ± 50 mV) for increased noise immunity. 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VMEElma 7-Slot VME64x Chassis. )) Pixus has a wide range of CompactPCI, VME, VME64x, and other backplanes available off-the-shelf. ANSI / VITA conform portfolio of VME and VME64x backplanes: Up to 21 Slots; 3 U and 6 U rack height; ANSI / VITA 1-1994 VME64; ANSI / VITA 1. Subrack based, sheet metal, desktop or tower configurations. Rows "A", "B", and. 7-2003 (R2009) Greater than 64MHz high speed design Shielded signal lines & Controlled Imepedence Active. Product Type: Backplane; Number of Slots: 10; Rack Height: 6 U; Backplane Type: VME64x with EDC The Elma Electronic VME64x backplane series is designed to fully comply with the ANSI/VITA VME extension standard. 5 V – Address, address modifier and data lines are active high. Extended Description. VME64x Front panel. The extra 1U provides room for extra power bugs or busbars. 6UX160MM horizontal card cage; 3-slot, P1P0P2 VME64x. 3 volts) and ground (GND) on P1 Pinout and 'User Defined' signals on P2. cPCI Backplanes Hartmann compactPCI backplane design is based on the HIGH-SPEED concept, and fully complies with the PICMG 2. Connector Type: DIN 41612, VME64x. cPCI Serial Backplanes Our serial. The new 160 pin DIN (5 row x 32 pin) adds rows "z" and "d". Robust contact system. 6U VME64x Backplane 21-slot with P0, compliant with ANSI/VITA 1. The extra 1U provides room for extra power bugs or busbars. Discreet 3U high VME64 and VME64x backplanes are fully RoHS compliant and perform to ANSI/VITA 1. The A+C rows are bussed in all slots. Bei höheren Anforderungen an die Schutzklasse, z. Vector offers a comprehensive range of VMEbus backplanes from 2 to 21 slots. PICMG 6-10 slots. 6U VME64x Backplane 15-slot without P0, compliant with ANSI/VITA 1. 7 Increased Current. 1-1997, VME extension, and VITA 1. 1-1997 VME64 Extension Standard, ANSI/VITA 1. 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VME VME-VME64 6U 162 Series. The extra 1U provides room for extra power bugs or busbars. 1-1997 VME64x; ANSI / VITA 1. VXS adds additional high-speed serial data transfer up to 10 Gbps to the backplane and supports both Single and Dual Star topologies. General Backplane Specification for VME and VME64x Slot Count : 2-21 slot options Size : “True” 6U, 10. 1-1997). 5-2003 VME2eSST Specification, ANSI/VITA 1.